MultiTest Reef Special Seachem is a combined test kit designed to accurately measure three key parameters in a reef aquarium: phosphate, silicate, and iodine/iodide. It combines three MultiTest tests in one box, allowing reliable seawater analysis using a multi-cavity plate that facilitates the simultaneous reading of multiple parameters.
Measured parameters: phosphate, silicate, iodine/iodide.
Compatibility: marine and reef aquarium.
Number of tests: more than 75 tests per parameter.
Method: chemical colorimetry.
Multi-cavity plate: up to 6 tests in parallel.
Reference solutions: included for validation of measurements.
The silicate test measures soluble silicates down to concentrations below 0.5 mg/L. Results are expressed in silicate. To obtain the concentration in silicon, simply multiply the measured value by 0.3. In reef aquariums, it is recommended to maintain silicate at 1 mg/L or less to limit the development of diatom algae.
The phosphate test measures inorganic phosphate at concentrations below 0.05 mg/L. It uses a yellow-green-blue color scale that is easy to interpret in seawater. In freshwater, phosphate concentrations may exceed the measurement range and require prior dilution of the sample.
The iodine/iodide test provides a precise quantitative measurement of this essential element for the growth of soft corals and hard corals. It measures iodine or iodide at concentrations below 0.005 mg/L, with a reading scale up to 0.10 mg/L.
Phosphate range: from 0 to 3 mg/L.
Phosphate precision: detectable increments from 0.001 to 0.1 mg/L.
Silicate range: from 0 to 25 mg/L.
Silicate precision: detectable increments from 0.1 to 1 mg/L and from 0.01 to 0.1 mg/L.
Iodine/iodide range: from 0 to 0.1 mg/L.
Iodine/iodide precision: detectable increments from 0.0025 to 0.005 mg/L.
The use of reference solutions is not essential to perform the tests. However, they allow verifying the reliability of the kit by replacing the aquarium sample with a reference solution of known value.
All MultiTest tests are performed on a white opaque multi-cavity plate. The color charts have a 5 cm reading window allowing precise color comparison and reliable interpretation of results.
| Element | Detail |
|---|---|
| Silicate reagents 1a, 1b, 2, 3 | Included |
| Silicate reference solution | Included |
| Silicate color chart | Included |
| Phosphate reagents 1 and 2 | Included |
| Phosphate reference solution | Included |
| Phosphate color chart | Included |
| Iodine/iodide reagents | Included |
| Iodine/iodide reference solution | Included |
| Iodine/iodide color chart | Included |
| Pipettes and stirring rods | Included |
| Low range cuvettes | Included |
| Multi-cavity test plates | 3 plates included |
| User manuals | Included |
Keep out of reach of children. Reagents may be irritating. Avoid contact with skin and eyes. Do not ingest. In case of contact, rinse thoroughly with water.